Air Cooled Cables

A wide range of air-cooled jumper connectors are available to ISO standards. These are based on six cross-sectional areas and are available wit hvarious terminal configurations and in any length.
All air-cooled jumper connections are shrouded in oil and water resistant neoprene duck tubing.
Hose which is free from silicone can either be as shown or perforated.
Technical Data
Table A
Cross-section (m²) |
||||||
250 |
315 |
400 |
500 |
630 |
800 |
|
a |
13 |
15 |
18 |
21 |
24 |
32 |
b |
32 |
32 |
32 |
32 |
38 |
38 |
D |
38 |
40 |
45 |
50 |
55 |
65 |
L* |
Permissable permanent current /2p A** |
|||||
160 |
2800 |
3150 |
3550 |
4000 |
- |
- |
180 |
2650 |
3000 |
3350 |
3750 |
- |
- |
200 |
2500 |
2800 |
3150 |
3550 |
- |
- |
224 |
2360 |
2650 |
3000 |
3350 |
3750 |
- |
250 |
2240 |
2500 |
2800 |
3150 |
3550 |
4000 |
280 |
2120 |
2360 |
2650 |
3000 |
3350 |
3750 |
315 |
2000 |
2240 |
2500 |
2800 |
3150 |
3550 |
355 |
1900 |
2120 |
2360 |
2650 |
3000 |
3350 |
400 |
1800 |
2000 |
2240 |
2500 |
2800 |
3150 |
450 |
1700 |
1900 |
2120 |
2360 |
2650 |
3000 |
500 |
1600 |
1800 |
2000 |
2240 |
2500 |
2800 |
560 |
- |
- |
1800 |
2120 |
2360 |
2650 |
630 |
- |
- |
1800 |
2000 |
2240 |
2500 |
* The dimensions of the secondary connecting cables shall be given in figure 1 and table A
** The permissable secondary current /x, at a given duty factor x may be calculated from ![]()
Figure 1 - Dimensioinal Layout