AC Transformers - Technical Data

- Technical Data

Technical specifications for the transformers are given below. There are two frame sizes. H & J. The 32kVA is only provided in the H size. All other transformers are provided in the J size. The fixing dimensions are given on the technical drawings, which are available on request. All J size transformers are interchangeable and all secondary connections on H & J transformers are identical, allowing shunts and bushbars to be standard

Primary connection terminal arrangements are common for all sizes from 32kVA to 61kVA. Connections for 76kVA and 103kVA are larger, to permit connection of larger dimension primary cables.

Different aluminium alloy connection boxes can be offered, either with direct connection through 'Multi-Contact' type plugs or cable glands. Special boxes can be manufactured when needed by the customer.

Thermostats are set at: Primary: 140°
  Secondary:  80°
Toroid information: 150mV/kA±1.5% at 1 KOhms resistance


Transform.
size
Frame
size
Sec. volts
(no load)
Nominal
sec.amps
kA
Continuous
sec. amps
kA
 Weight
kg
Colour

32kVA

H

5.6

5.7

4.0
19

RAL4005 Purple

48kVA

 J

6.3

7.6

5.4
28

RAL5015 Blue

54kVA

 J

7.1

7.6

5.4
29

RAL6001 Green

61kVA

 J

8.0

7.6

5.4
33

RAL7005 Grey

76kVA

 J

10.0

7.6

5.4
37

RAL1004 Yellow

103kVA

 J

13.5

7.6

5.4
50

RAL8001 brown